100PX2K1RA4

Overall Cable Diameter

86.1mm -101.4mm

GTIN/EAN Code

5052625417409

ETIM Classification

EC000441

Downloads

Description

The PX2K range of compound barrier cable glands are for use in heavy duty applications in Explosive Atmospheres. Designed to prevent gas, vapour or fluid from migrating through a cable, or else prevent flame transmission from a Flameproof type ‘d’ enclosure, as determined by IEC 60079-14


Features

  • Metal-to-metal armour clamping
  • Direct and remote installation
  • Compound barrier type flameproof seal
  • Controlled outer load retention seal
  • Unique OSTG prevents overtightening
  • Integral protected deluge seal
  • -60˚C to +85˚C
  • Globally marked, UL, cCSAus, IECEx, ATEX and UKEX
  • Superior EMC performance
  • Compound barrier seals around internal cable cores after removing any
  • inner cable sheath/bedding; completely eliminating any risk of coldflow

Additional Information

Technical Specification
Maximum Across Flats 'AF' 127
Maximum Across Flats 'AF' (Imperial) 5
Maximum Across Corners 'AC' (Imperial) 5.5
Compliance Standard Metric Parallel Thread to ISO 965-1:2013, ISO 965-3:1998 (& Corrigendum 1 - 2009), medium fit (6g) for external thread
Refresh Comments Imperial data refresh
Minimum Armour Thickness W (Stepped) Cone 'W1' (Imperial) 0.124
Minimum Armour Thickness W (Stepped) Cone 'W1' 3.15
Maximum Armour Thickness W (Stepped) Cone 'W1' (Imperial) 0.157
Maximum Armour Thickness W (Stepped) Cone 'W1' 4
Minimum Armour Thickness X (Grooved) Cone 'X1' (Imperial) 0.03
Minimum Armour Thickness X (Grooved) Cone 'X1' 0.8
Maximum Armour Thickness X (Grooved) Cone 'X1' (Imperial) 0.06
Minimum Cable Bedding Diameter 'IB' (Imperial) 0
Maximum Cable Bedding Diameter 'IB' 85.9
Maximum Cable Bedding Diameter 'IB' (Imperial) 3.38
Minimum Overall Cable Diameter 'OS' 86.1
Minimum Overall Cable Diameter 'OS' (Imperial) 3.39
Maximum Overall Cable Diameter 'OS' 101.4
Maximum Overall Cable Diameter 'OS' (Imperial) 3.99
Minimum Thread Length 'TL' 20
Minimum Thread Length 'TL' (Imperial) 0.79
Certification
ATEX Certificate Number CML 18ATEX1325X
ATEX Code of Protection ^ I M2 Ex db I Mb, Ex eb I Mb; ^ II 2G 3G 1D Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
ATEX Compliance Standards EN 60079-0, -1, -7, -15, -31
IECEx Certificate Number IECEx CML 18.0182X
IECEx Code of Protection Ex db I Mb, Ex eb I Mb, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
IECEx Compliance Standards IEC 60079-0, -1, -7, -15, -31
IECEx Logo Filename iecexlogo.jpg
IECEx Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/990ba9ce/6447a914b902aa64e3000252/iecexlogo.jpg
UKEX Certificate Number CML 21UKEX1214X, CML 21UKEX4215X
CSA Certificate Number CSA Certificate
CSA Code of Protection Class I, Div 1 and 2, Groups A, B, C, and D; Class II, Div 1 and 2, Groups E, F and G; Class III, Div 1 and 2; Type 4X; Oil Resistance II; Class I, Zone 1, AEx d IIC Gb, AEx e IIC Gb; Class I, Zone 2, AEx nR IIC Gc, Ex nR IIC Gc; Class I, Zone 20 AEx ta IIIC Da
CSA Logo Filename cCSAusLogo.jpg
CSA Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/04240f8d/644a5309f631055fb7000001/cCSAusLogo.jpg
EAC Certificate Number EAЭC RU C-GB.AꙢ07.B.04595/22
EAC Code of Protection { 1Ex db IIC Gb X, { 1Ex e IIC Gb X, { 2Ex nR IIC Gc X, { Ex ta IIIC Da X
EAC Logo Filename eaclogo.jpg
EAC Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/0802384c/64425917f6310520f0000001/eaclogo.jpg
KCs Certificate Number 13-AV4BO-0452, 13-AV4BO-0457
KCs Logo Filename kcslogo.jpg
KCs Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/0802384c/64425917f6310520f0000007/kcslogo.jpg
CCC Certificate Number 2020322313003190
CCC Logo Filename ccclogo.jpg
CCC Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/cf29f9f6/644a38e4f631055a56000001/ccclogo.jpg
RETIE Certificate Number 3866
PESO Certificate Number P533772/8, P548696/12
ECAS Certificate Number 23-03-64838/E23-02-065451/NB0007
ECAS Logo Filename ecaslogo.jpg
SANS Certificate Number MS-XPL21962 21.0305X
ETIM
Thread type Metric
Nominal thread size metric/PG 100
Pitch thread 2
Thread length 20
Wrench width 127
Hexagon angular dimension 139.7
Suitable for cable diameter 86.1
Suitable for cable diameter max 101.4
Material Metal
Material quality Stainless steel 316 (V4A)
Surface protection Untreated
Halogen free Yes
Glass-fibre reinforced No
Degree of protection (IP) IP68
Shock resistant Yes
Colour Stainless steel
Bend radius protection/trumpet flare No
With locknut No
Snapping in opening No
Model Straight
Multi seal area No
Flat cable coupling No
With strain relief No
Type of sealing Sealing ring
Explosion-tested version Yes
Operating temperature max 85
For Ex-zone gas 1, 2
For Ex-Zone dust 20, 21, 22
For armoured cable Yes
EMC-version Yes
Screened Yes

Certificates

2D/3D Illustrations