115E2FX1RA5310

Overall Cable Diameter

101.5mm -110.2mm

GTIN/EAN Code

5052625407578

ETIM Classification

EC000441

Downloads

Description

The E2FX range of cable glands are for use in heavy duty applications in Explosive Atmospheres. Designed with a seal on both the inner and the outer sheath.


Features

  • Effectively earths / grounds lead sheathed cables
  • Metal-to-metal armour clamping
  • Direct and remote installation
  • Displacement type flameproof inner seal
  • Controlled outer load retention seal
  • Designed to reduce the effects of coldflow, see CMP Technical Document TS001
  • Unique OSTG prevents overtightening
  • -60˚C to +130˚C
  • Globally marked cCSAus, IECEx, ATEX and UKEX
  • Superior EMC performance

Additional Information

Technical Specification
Maximum Across Flats 'AF' 133.4
Maximum Across Flats 'AF' (Imperial) 5.26
Maximum Across Corners 'AC' (Imperial) 5.78
Compliance Standard NPT Tapered Thread to ANSI B1.20.1:2006 / ASME B1.20.1:2013 gauging to clause 8.1 for external thread & IEC 60981:2004-05
Refresh Comments Imperial data refresh
Minimum Armour Thickness X (Grooved) Cone 'X1' (Imperial) 0.03
Minimum Armour Thickness X (Grooved) Cone 'X1' 0.8
Maximum Armour Thickness X (Grooved) Cone 'X1' (Imperial) 0.06
Minimum Lead Sheath Diameter 86
Minimum Lead Sheath Diameter (Imperial) 3.39
Maximum Lead Sheath Diameter 94.1
Maximum Lead Sheath Diameter (Imperial) 3.7
Minimum Overall Cable Diameter 'OS' 101.5
Minimum Overall Cable Diameter 'OS' (Imperial) 4
Maximum Overall Cable Diameter 'OS' 110.2
Maximum Overall Cable Diameter 'OS' (Imperial) 4.34
Minimum Thread Length 'TL' 44
Minimum Thread Length 'TL' (Imperial) 1.73
Certification
ATEX Certificate Number CML 18ATEX1324X
ATEX Code of Protection ^ I M2 Ex db I Mb, Ex eb I Mb; ^ II 2G 3G 1D Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
ATEX Compliance Standards EN 60079-0, -1, -7, -15, -31
IECEx Certificate Number IECEx CML 18.0181X
IECEx Code of Protection Ex db I Mb, Ex eb I Mb, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
IECEx Compliance Standards IEC 60079-0, -1, -7, -15, -31
IECEx Logo Filename iecexlogo.jpg
IECEx Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/990ba9ce/6447a914b902aa64e3000252/iecexlogo.jpg
UKEX Certificate Number CML 21UKEX1252X, CML 21UKEX4253X
CSA Certificate Number CSA Certificate
CSA Code of Protection CANADA: Class I, Div 2, Groups A, B, C and D; CANADA AND US: Class II, Div 2, Groups E, F, and G; Class III, Div 1 and 2; Enclosure Type 4X; Ex e II; Ex nR II
CSA Logo Filename cCSAusLogo.jpg
CSA Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/04240f8d/644a5309f631055fb7000001/cCSAusLogo.jpg
EAC Certificate Number EAЭC RU C-GB.AꙢ07.B.02515/20
EAC Code of Protection { 1Ex db IIC Gb X, { 1Ex e IIC Gb X, { 2Ex nR IIC Gc X, { Ex ta IIIC Da X
EAC Logo Filename eaclogo.jpg
EAC Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/0802384c/64425917f6310520f0000001/eaclogo.jpg
KCs Certificate Number 14-GA4BO-0257X
KCs Logo Filename kcslogo.jpg
KCs Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/0802384c/64425917f6310520f0000007/kcslogo.jpg
CCC Certificate Number 2020322313002870
CCC Logo Filename ccclogo.jpg
CCC Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/cf29f9f6/644a38e4f631055a56000001/ccclogo.jpg
RETIE Certificate Number 3866
PESO Certificate Number P533772/7, P548696/2
ECAS Certificate Number 23-03-64823/E23-02-065420/NB0007
ECAS Logo Filename ecaslogo.jpg
SANS Certificate Number MS-XPL21804 21.0010X
ETIM
Thread type NPT
Nominal thread size inch/gas pipe thread 4 inch
Thread length 44
Wrench width 133.4
Hexagon angular dimension 146.7
Suitable for cable diameter 101.5
Suitable for cable diameter max 110.2
Material Metal
Material quality Brass
Surface protection Nickel-plated
Halogen free Yes
Glass-fibre reinforced No
Degree of protection (IP) IP66
Shock resistant Yes
Colour Nickel
Bend radius protection/trumpet flare No
With locknut No
Snapping in opening No
Model Straight
Multi seal area No
Flat cable coupling No
With strain relief No
Type of sealing Sealing ring
Explosion-tested version Yes
Operating temperature max 130
For Ex-zone gas 1, 2
For Ex-Zone dust 20, 21, 22
For armoured cable Yes
EMC-version Yes
Screened Yes

Certificates

2D/3D Illustrations