25SPX2KPBREX1RA032

Overall Cable Diameter

14mm -22mm

GTIN/EAN Code

5052625418338

ETIM Classification

EC000441

Downloads

Description

The PX2KPBREX range of RapidEx barrier cable glands are for use in heavy duty applications in Explosive Atmospheres. Designed to prevent gas, vapour or fluid from migrating through a cable, or else prevent flame transmission from a Flameproof type ‘d’ enclosure, as determined by IEC 60079-14. The RapidEx liquid pour sealing system enhances reliability, reduces risk and significantly reduces curing time.


Features

  • Effectively earths / grounds lead sheathed cables
  • RapidEx liquid pour sealing system reduces installation time
  • Metal-to-metal armour clamping
  • Direct and remote installation
  • Integral protected deluge seal
  • Controlled outer load retention seal
  • -60˚C to +85˚C

Additional Information

Technical Specification
Maximum Across Flats 'AF' 37.5
Maximum Across Flats 'AF' (Imperial) 1.48
Maximum Across Corners 'AC' (Imperial) 1.63
Compliance Standard NPT Tapered Thread to ANSI B1.20.1:2006 / ASME B1.20.1:2013 gauging to clause 8.1 for external thread & IEC 60981:2004-05
Refresh Comments Imperial data refresh
Minimum Armour Thickness W (Stepped) Cone 'W1' (Imperial) 0.049
Minimum Armour Thickness W (Stepped) Cone 'W1' 1.25
Maximum Armour Thickness W (Stepped) Cone 'W1' (Imperial) 0.063
Maximum Armour Thickness W (Stepped) Cone 'W1' 1.6
Minimum Armour Thickness X (Grooved) Cone 'X1' (Imperial) 0.02
Minimum Armour Thickness X (Grooved) Cone 'X1' 0.4
Maximum Armour Thickness X (Grooved) Cone 'X1' (Imperial) 0.05
Minimum Lead Sheath Diameter 11.1
Minimum Lead Sheath Diameter (Imperial) 0.44
Maximum Lead Sheath Diameter 19.3
Maximum Lead Sheath Diameter (Imperial) 0.76
Minimum Overall Cable Diameter 'OS' 14
Minimum Overall Cable Diameter 'OS' (Imperial) 0.55
Maximum Overall Cable Diameter 'OS' 22
Maximum Overall Cable Diameter 'OS' (Imperial) 0.87
Minimum Thread Length 'TL' 20.2
Minimum Thread Length 'TL' (Imperial) 0.8
Certification
ATEX Certificate Number CML 18ATEX1325X
ATEX Code of Protection ^ I M2 Ex db I Mb, Ex eb I Mb; ^ II 2G 3G 1D Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
ATEX Compliance Standards EN 60079-0, -1, -7, -15, -31
IECEx Certificate Number IECEx CML 18.0182X
IECEx Code of Protection Ex db I Mb, Ex eb I Mb, Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
IECEx Compliance Standards IEC 60079-0, -1, -7, -15, -31
IECEx Logo Filename iecexlogo.jpg
IECEx Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/990ba9ce/6447a914b902aa64e3000252/iecexlogo.jpg
UKEX Certificate Number CML 21UKEX1214X, CML 21UKEX4215X
EAC Certificate Number EAЭC RU C-GB.AꙢ07.B.04595/22
EAC Code of Protection { 1Ex db IIC Gb X, { 1Ex e IIC Gb X, { 2Ex nR IIC Gc X, { Ex ta IIIC Da X
EAC Logo Filename eaclogo.jpg
EAC Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/0802384c/64425917f6310520f0000001/eaclogo.jpg
KCs Certificate Number 19-AV4BO-0372X
KCs Logo Filename kcslogo.jpg
KCs Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/0802384c/64425917f6310520f0000007/kcslogo.jpg
CCC Certificate Number 2020322313003190
CCC Logo Filename ccclogo.jpg
CCC Logo https://cdn.pimber.ly/public/asset/raw/62c2cfa03a6b3a001b063277/cf29f9f6/644a38e4f631055a56000001/ccclogo.jpg
RETIE Certificate Number 3866
PESO Certificate Number P533772/8, P548696/12
ECAS Certificate Number 23-03-64838/E23-02-065451/NB0007
ECAS Logo Filename ecaslogo.jpg
SANS Certificate Number MS-XPL21962 21.0305X
ETIM
Thread type NPT
Nominal thread size inch/gas pipe thread 3/4 inch
Thread length 20.2
Wrench width 37.5
Hexagon angular dimension 41.3
Suitable for cable diameter 14
Suitable for cable diameter max 22
Material Metal
Material quality Brass
Surface protection Untreated
Halogen free Yes
Glass-fibre reinforced No
Degree of protection (IP) IP68
Shock resistant Yes
Colour Brass
Bend radius protection/trumpet flare No
With locknut No
Snapping in opening No
Model Straight
Multi seal area No
Flat cable coupling No
With strain relief No
Type of sealing Sealing ring
Explosion-tested version Yes
Operating temperature max 85
For Ex-zone gas 1, 2
For Ex-Zone dust 20, 21, 22
For armoured cable Yes
EMC-version Yes
Screened Yes

Certificates

2D/3D Illustrations