The A2e100 range of cable glands are for use in heavy duty applications in Explosive Atmospheres. Designed to comply 100% with the requirements of IEC 60079-0. For use in Ex applications where external clamping of the cable is not practical or desireable.
Features
Complies 100% with IEC 60079-0 cable retention requirements
No special conditions for safe use
No external cable clamping required by certification
Displacement type seal
Deluge protected
-60˚C to +130˚C
Internationally marked, UKEX, IECEx and ATEX
10mm thread lengths available upon request (sizes 32 and below)
Ingress protection disc available on request
Additional Information
Technical Specification
Maximum Across Flats 'AF'
46
Maximum Across Flats 'AF' (Imperial)
1.81
Maximum Across Corners 'AC' (Imperial)
1.99
Compliance Standard
NPT Tapered Thread to ANSI B1.20.1:2006 / ASME B1.20.1:2013 gauging to clause 8.1 for external thread & IEC 60981:2004-05
Refresh Comments
Imperial data refresh
Minimum Overall Cable Diameter 'OS'
19
Minimum Overall Cable Diameter 'OS' (Imperial)
0.75
Maximum Overall Cable Diameter 'OS'
25.5
Maximum Overall Cable Diameter 'OS' (Imperial)
1
Minimum Thread Length 'TL'
25.6
Minimum Thread Length 'TL' (Imperial)
1.01
Certification
ATEX Certificate Number
CML 18ATEX3309
ATEX Code of Protection
^ I M2 Ex eb I Mb; ^ II 2G 3G 1D Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
ATEX Compliance Standards
EN 60079-0, -7, -15, -31
IECEx Certificate Number
IECEx CML 18.0174
IECEx Code of Protection
Ex eb I Mb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da