40E2W1RA134

Overall Cable Diameter

27.9mm -40.4mm

GTIN/EAN Code

5052625416570

ETIM Classification

EC000441

Downloads

Description

The E2W range of cable glands are for use in heavy duty applications in Industrial Areas (Safe Areas). Designed with a seal on both the inner and the outer sheath.


Features

  • Effectively earths / grounds lead sheathed cables
  • Metal-to-metal armour clamping
  • Direct & remote installation
  • Permanently crimped, low impedance earth termination
  • Secure against self-loosening
  • Displacement type inner seal
  • Controlled outer ‘load retention’ seal
  • Unique OSTG prevents overtightening
  • Deluge protection option
  • -60˚C to +130˚C
  • Superior EMC performance

Additional Information

Technical Specification
Maximum Across Flats 'AF' 55
Maximum Across Flats 'AF' (Imperial) 2.17
Maximum Across Corners 'AC' (Imperial) 2.38
Compliance Standard NPT Tapered Thread to ANSI B1.20.1:2006 / ASME B1.20.1:2013 gauging to clause 8.1 for external thread & IEC 60981:2004-05
Refresh Comments Imperial data refresh
Minimum Armour Thickness W (Stepped) Cone 'W1' (Imperial) 0.063
Minimum Armour Thickness W (Stepped) Cone 'W1' 1.6
Maximum Armour Thickness W (Stepped) Cone 'W1' (Imperial) 0.079
Maximum Armour Thickness W (Stepped) Cone 'W1' 2
Minimum Lead Sheath Diameter 22
Minimum Lead Sheath Diameter (Imperial) 0.87
Maximum Lead Sheath Diameter 31.2
Maximum Lead Sheath Diameter (Imperial) 1.23
Minimum Overall Cable Diameter 'OS' 27.9
Minimum Overall Cable Diameter 'OS' (Imperial) 1.1
Maximum Overall Cable Diameter 'OS' 40.4
Maximum Overall Cable Diameter 'OS' (Imperial) 1.59
Minimum Thread Length 'TL' 25.6
Minimum Thread Length 'TL' (Imperial) 1.01
Certification
Industrial Certificate Number Sira 10Y9148U
ETIM
Thread type NPT
Nominal thread size inch/gas pipe thread 1 1/4 inch
Thread length 25.6
Wrench width 55
Hexagon angular dimension 60.5
Suitable for cable diameter 27.9
Suitable for cable diameter max 40.4
Material Metal
Material quality Aluminium
Surface protection Untreated
Halogen free Yes
Glass-fibre reinforced No
Degree of protection (IP) IP66
Shock resistant Yes
Colour Silver
Bend radius protection/trumpet flare No
With locknut No
Snapping in opening No
Model Straight
Multi seal area No
Flat cable coupling No
With strain relief No
Type of sealing Sealing ring
Explosion-tested version No
Operating temperature max 130
For Ex-zone gas None
For Ex-Zone dust None
For armoured cable Yes
EMC-version Yes
Screened Yes

Certificates

2D/3D Illustrations